Photobiological safety is nothing exclusive to SSL sources, but must be evaluated for all light sources. Due to their similarity to laser diodes, LEDs were originally covered by the laser safety standard IEC 60825, which often led to an overestimation of the risks. Since 2009 LEDs and SSL sources have therefore been subject to IEC 62471 “Photobiological safety of lamps and lamp systems”. All lamp and luminaires brought onto the market must be classified according to this standard.

The standard identifies two health hazards that can be caused by visible light. Intense light may lead to retinal burns, a hazard that is easily avoided by normal aversive behavior. However, blue light between 400 nm and 500 nm may cause photochemical damage to the retina, a hazard that is difficult to assess by users. This so-called blue light hazard may lead to degeneration of the macula. The corresponding weighting function ranges from 300 nm to 700 nm with a maximum at 437 nm. In view of the distinctive blue peak of white LEDs, the question arises as to whether SSL sources are hazardous.

Depending on the radiance levels, BLH sensitivity and exposure times, IEC 62471 divides light sources into four risk groups ranging from 0 (no risk) to 3 (always dangerous). Risk groups 1 and 2 are sources that are not dangerous under normal behavior and aversion reactions. The standard also describes measurement equipment and procedures for the correct assessment of the risk classes of light sources. Additionally, IEC/TR 62778 explains how to apply IEC 62741 for simpler assessment of the BLH for lamps and luminaires.

Accurate risk assessment is a challenging task for the experimenter, and starts with the selection of the correct test equipment. Today’s measurement instrument of choice is often an array spectrometer instead of the hard-to-handle double monochromator suggested by the standard. But even high-end array spectrometers must offer advanced stray light correction methods to achieve the required high dynamic measuring range, especially in the less sensitive blue region. Carefully designed test adapters are necessary to ensure correct and reproducible test geometries. With such equipment, testing labs – which should be accredited to ISO17025 – can reliably assess the risk class of lighting products.

Several studies have evaluated the risk classes of various kinds of SSL sources, lamps and luminaires. In general, SSL sources were not found to pose a greater risk to the user than conventional sources. Most luminaires with non-directly visible LEDs were assigned to risk class 0. Only luminaires with directly visible LEDs ended up in risk class 1 or, in some cases, in class 2, which the standard still classifies as free of risk under normal use and aversion reaction – just like conventional sources.

I must emphasize that these positive results should not encourage manufacturers to underestimate the importance of safety assessment of light sources. Research on the safety aspects of lighting will continue, and only accredited labs using state-of-the-art test equipment will be able to ensure a reliable risk assessment. Consumers may rightfully expect lamps and luminaires providing light that is safe in every aspect. Otherwise, SSL lighting will not be able to assert itself in the long term.

Dr. Thomas Attenberger

Thomas Attenberger received his PhD in Physics from the University of Regensburg in 1992 for his work in the field of high-resolution spectroscopy with a thesis on “Persistent spectral hole burning”. He worked for several years as R&D project leader at a Munich high tech company, where one of his tasks was to establish a spectroscopy lab for performing basic research for optical sensor development. Attenberger joined Instrument Systems GmbH in 2001 as sales and product manager for LED test and measurement equipment. Since 2009 he has held the position of Vice President Sales at Instrument Systems GmbH, in which he is responsible for worldwide sales and marketing activities. This position brings him into close contact with other major players in the LED and SSL lighting industry.



Source link

admin

Share
Published by
admin

Recent Posts

High TLCI Illumination for Accurate Color in Telework & Indoor Video Recording — LED professional

Over the past 50 years, Nichia has demonstrated its commitment to improving the overall performance…

3 years ago

Blueglass to Aquire US Laser Diode Facility — LED professional

To fund the acquisition and ongoing operation of the production facility, BluGlass has secured A$3.4…

3 years ago

High-performance for wavelengths in infrared

New CAS 140D IR spectroradiometer with improved optical and electronic components offer the user higher…

3 years ago

Seoul Semiconductor Relocates Headquarters of Automobile Division to Germany — LED professional

SSC boasts world's only LED and LD technology for vehicles using all wavelengths of light…

3 years ago

Panel technology: HELLA develops new design concepts for the vehicle front end

  ​E-cars do not have a classic radiator grille, so the front of the vehicle…

3 years ago

Data Reporting, Diagnostics, Sensors and NLCs Added to ANSI C137.4-2021 Standard for Digital Lighting Control — LED professional

“We welcome the further alignment of ANSI C137.4-2021 and D4i, which is expected to lead…

3 years ago